Description
READY TO USE
The CMeX12S is ready to use with no configuration required in the field. The possibility of stacking the CMeX12S, enables one CMe2100 to handle multiple M-Bus 2-wire buses isolated from each other. After installation, the CMeX12S shows an indication if the installation was successful.
STANDARD OPEN PROTOCOLS
The standard open protocol design works with any software supporting the M-Bus standard. Its transparent M-Bus dataflow require no manufacture specific protocols.
FLEXIBLE
The CMeX Series contains modules with various functions to meet a great variety of customer demands. The series contains for example I/O modules and D/A modules to read input signals or control output signals.
COST EFFECTIVE
The modular and expandable design allows the customer to select a suitable level based on price and functionality. The initial cost is low and additional modules can easily be added to existing installations, which provides a future proof solution.
Technical data
Mechanics
|
Casing material
|
Polyamide
|
Protection class
|
IP20
| |
Dimensions
|
90 x 65 x 108 mm
| |
Weight
|
220 g
| |
Connection M-Bus
|
Pin terminal solid wire 0.6-0.8 Ø mm and screw terminal cable 0.25-2.5 mm², 0.5 Nm tightening torque
| |
Mounting
|
DIN Mounted
| |
Power supply
|
Screw terminal cable 0.75-2.5 mm², 0.5 Nm tightening torque
| |
Electrical
|
Nominal Voltage
|
100-240 VAC
|
Voltage range
|
-10 % to +10 % of nominal voltage
| |
Frequency
|
50/60 Hz
| |
Power consumption (max)
|
25 W
| |
Power consumption (nom)
|
1.5 mA x M-Bus slaves + 1 W
| |
Installation category
|
CAT 3
| |
Environmental
|
Operating temperature range
|
-30 to +55 °C
|
Storage temperature range
|
-40 to +85 °C
| |
Operating humidity max
|
80 % RH temperatures up to 31 °C, decreasing linearly to 50 % RH at 40 °C
| |
Pollution
|
Degree 2
| |
Operating altitude
|
0-2000 m
| |
Usage
|
Indoor use only, can be extended with IP67 enclosure for outdoor use
| |
User interface
|
Green LED
|
Power
|
Red LED
|
Error
| |
Yellow LED
|
RX
| |
Yellow LED
|
TX
| |
Push button
|
Not used
| |
M-Bus
|
M-Bus standard
|
EN 13757
|
M-Bus baud rate
|
300, 2400 Bit/s
| |
Maximum connected M-Bus meters
|
128
| |
Maximum cable length
|
5000 m
| |
Max load capacitance
|
1.5 uF
| |
Light collision detect
|
>28 to 500 mA
| |
RS232 to M-Bus
|
Yes
| |
Break signal length M-Bus 2-wire and right IR interface
|
45 ms
| |
Break signal RS232 interface and left IR interface
|
45 ms
| |
Nominal voltage
|
42 VDC
| |
Maximum idle current
|
200 mA
| |
IR Interface
|
Yes
| |
Pass Through
|
Yes. Maximum of 4 CMeX series products side by side
| |
Compatibility
|
All M-Bus meters, all ABB meters with IR interface, CMeX Series products
| |
Approvals
|
EMC
|
EN 61000-6-2, EN 61000-6-3
|
Safety
|
EN 61010-1, CAT 3
|
Downloads
| CMeX10 Series Product sheet | CMeX10 Series DIN-Mounted M-Bus extenders product sheet |
| CMeX10 Series Declaration of conformity | CMeX10 Series Declaration of conformity |
| CMeX10S-13S Quick manual | CMeX10S-13S DIN-Mounted M-Bus master for up to 256 slaves quick manual | |
| CMeX10 Series User's manual | CMeX10 Series DIN mounted M-Bus extenders user's manual |
Knowledge base